10 Kronos First Stage Service Manual
15. Fit the spring base (127565), the spring (127567), and
the washer (127568).
16. Fit the MP screw (127566) then fit the washer (127586).
17. Reassembly of the dry chamber (Kronos Supreme)
Fit the diaphragm (119159) into its position in the dry
chamber (127577). Tighten the chamber at 2.5 m.kg
using the tool (122152)
18. Fit the washer (127587), the spring base (127565), the
spring (127567) and the washer (127568).
19. Screw the MP adjusting screw (127566) until you see
the first threads of the dry chamber.
ADJUSTING THE FIRST STAGE
a. Screw an MP gauge (0-25 bar) into one of the MP ports.
If the gauge is not fitted with an over-pressure valve,
then it is vital that the second stage is fitted so that it can
act as an over-pressure valve in the event of an HP leak.
b. Connect the first stage to a cylinder charged to 200bar.
Slowly open the cylinder valve to put the regulator under
pressure.
Once the MP has been adjusted, purge the second
stage about ten times. When this is finished check the
pressure gauge. The MP should be stable at the desired
value (8.5b or 9.5b depending on the regulator). Make
any further adjustments that may be necessary. Leave
the regulator under pressure for several minutes and
check that the MP remains stable. If the MP rises more
than 0.3 bar this indicates that there is a leak. Refer to
Table 1. Troubleshooting Guide.
20. Close the cylinder valve and completely purge the
regulator. Put the regulator under pressure once more
and check that the MP is stable.
If the MP is different, repeat steps 3 and 4 until a stable
pressure is obtained.
Attention: if the MP indicated rapidly
exceeds 9.5bar then this indicates a
HP leak. Close the cylinder valve
immediately and purge the regulator.
Refer to Table 1. Troubleshooting
Guide.
c. After checking that there is no leak, adjust the MP by
turning the adjusting screw: Screwing in increases the
MP, unscrewing reduces the MP.
Turn the screw by increments of 1/8 of a turn and purge the
regulator several times, using the second stage, after each
increment. Adjust the MP (see Table 5).