FIRST TO DIVE 7
17. Remove the body from the vice, turn it over, and recover
the seat (127585) using the seat tool (116236). Remove
the seat seal (124704)
18. Remove the MP (122233) and HP (122237) plugs.
Remove their O-rings (124703) et (124701).
END OF DISASSEMBLY
Before starting to re-assemble the regulator,
make sure that all replacement parts have
been cleaned and lubricated in accordance
with Procedure A : Cleaning and Lubricating
on page 14
.
RE-ASSEMBLY PROCEDURE
Fit a new lubricated O-ring (124704) on the seat (127585).
Slide the seat onto the tool (116236), push the seat into the
body (HP side) to position the seat and push with the tool.
1. Screw the holding tool (116320) into a port and grip the
body in a vice. Fit the valve (124624) (with its face
toward the inside of the body) and fir the spring
(122244).
2. Fit a new lubricated anti-extrusion washer (119129) then
a new lubricated O-ring (124612) in the spring block
(127562). Using a small brush add a little grease to the
inside of the spring block.
Note: Before continuing, closely examine the anti-
extrusion washer (119129). You will note that it
has a flat side and a concave side. For correct
assembly the concave side should be against the
O-ring, as shown in the picture below.
O-ring
nti extrusion washer