FIRST TO DIVE 11
FINAL ASSEMBLY (cf VE 103191)
1. With the regulator under pressure, insert the piston
(127581) into the dry chamber. Place the diaphragm
(127579) right to the bottom of the diaphragm screw
(127582). Screw it fully home on the body using a lug
spanner (129198)
2. Check that the MP is still stable (see table 5)
3. Close the cylinder valve and purge the regulator.
Remove the pressure gauge and replace the MP plug.
END OF REASSEMBLY
TEST IN WATER
Check that all the MP and HP plugs are in place and that a
correctly adjusted second stage is connected to the first
stage. Slowly open the cylinder valve to put the regulator
under pressure.
Immerse the first stage completely in water to check that
there are no leaks.
When you are sure that there is no leak, close the cylinder
valve and purge the regulator. Remove the first stage from
the cylinder and refit the dust cap.
If a leak has been detected then note its source and refer to
Table 1. Troubleshooting Guide.
Note: The following step should be carried
out with the regulator under pressure.
Note: Do not mistake any bubbles that are
trapped in the regulator with a leak. If there
is a leak there will be a constant stream of
bubbles.