16 Kronos First Stage Service Manual
Table 4. Torque values
REFERENCE N°
DESCRIPTION
FORCE
127583
Wet chamber nut
2.5 m.kg.
127577
Dry chamber nut
2.5 m.kg
127576
Yoke seat
2.5 m.kg.
127572
DIN seat
2.5 m.kg.
127573
DIN shutter screw
2.5 m.kg
129207
Yoke nose shutter
0.2 m.Kg
129202
DIN nose shutter
0.2 m.Kg
127582
Diaphragm nut
En butée
127562
Spring block
En butée
Table 5. Checking specifications
TEST
INSTRUCTIONS
SPECIFICATIONS
Leak Test
160 bar < Working pressure < 200 bar
No leak
Medium Pressure
160 bar < Working pressure < 200 bar
KRONOS standard and Supreme : MP at 9.5 bar ± 0.5 bar
MP Variation
160 bar < Working pressure < 200 bar
After purging the regulator several times, the MP should not
increase by more than 0.3 bar in 5-15 seconds.