4 Kronos First Stage Service Manual
4. The acronyms used:
LP: Low Pressure
MP: Medium Pressure
HP: High Pressure
5. Numbers in brackets indicate the part number of the
component shown on the exploded view attached.
DISASSEMBLY PROCEDURE
1. Unscrew the hoses from the first stage using the
appropriate spanner. Screw the holding tool (116320)
into a free HP port and grip the tool in a vice.
2. Disassembly of the ACD connection on the yoke
version.
Unscrew the yoke seat (127576).
Remove the assembly seat + yoke + yoke screw + dust
cap.
Remove the filter (A05106) and the seal (820016).
Remove the elastomer washer (127575)
2.1 Tighten the yoke screw, compressing the dust cap, grip
the assembly in a vice, tighten the hex nut of the yoke
seat. Using a 3mm allen key, turn it in a clockwise
direction to unscrew the nut (129207)
Note: Before commencing disassembly, consult
the exploded view to check the reference
numbers of all parts requiring replacement.
These parts should all be replaced by new parts
and should not be re-used on the pretext that
the regulator has seen little use since its
manufacture or since its last service.
A
ttention: Use only the special tool when
removing O-rings in order to avoid damaging the
seal recess. The slightest scratch on a sealing
surface could cause a leak. If a surface should be
damaged then this part should be replaced with a
new one. Do not use any pointed instrument or
metal tool to remove O-rings.